Insulation test device

Insulation test device ETL
Series ATS400 / Series 36

ETL insulation test devices are available with a test voltage of up to 10 kV. The insulation test devices of Series 36 are single test devices with measuring voltages up to 10000V. The maximum measurable insulation resistance is 10 GΩ.

Insulation test device

Insulation test device ETL Series ATS400 / Series 36

ETL insulation test devices are available with a test voltage of up to 10 kV. The insulation test devices of Series 36 are single test devices with measuring voltages up to 10000V. The maximum measurable insulation resistance is 10 GΩ.

WHAT IS AN ISO – INSULATION TEST?

ETL_Technologies_GmbH_Prüfart_elektrische_Isolationsprüfung

An insulation test is an electrical examination conducted to verify the insulation integrity of an electrical device or installation. In this test, the insulation resistance between the live parts and non-live parts of the device is measured.

This is done by applying a high voltage to the parts to be tested, and the insulation resistance is measured. A high insulation resistance measurement indicates that the insulation is intact, and there are no undesired electrical leakage currents. Insulation testing is crucial to ensure the safety of electrical devices and minimize the risk of electric shocks or other electrical hazards.

Request your inquiry now
quickly and effortlessly!

HOW IS AN INSULATION TEST CONDUCTED?

Here are the basic steps to conduct an insulation test:

  1. Preparation:
    Ensure that the device is turned off and disconnected from the power grid. Also, check whether the testing equipment is functioning properly and calibrated.
  2. Connection of the Testing Equipment:
    Connect the testing equipment to the test points of the device. Ensure that the connection is firm and secure.
  3. Setting the Test Voltage:
    Set the desired test voltage on the testing equipment. The test voltage depends on the specific requirements of the device or the standard being followed.
  4. Conducting the Test:
    Turn on the testing equipment and initiate the insulation test. The testing equipment generates a high voltage applied to the device or component. The duration of the test may vary based on requirements.
  5. Assessment of the Result:
    The measurement results are provided in ohms. There are various standards and regulations that specify the minimum values for insulation resistance that must be met.

 

During the complete execution, safety guidelines according to EN 50191 must be followed. It is crucial that the test is performed by trained personnel due to the use of high voltages that can lead to dangerous situations. Additionally, the lines or devices to be tested should be de-energized before the test to prevent accidents.

Request your inquiry now
quickly and effortlessly!

COMBINATION TEST DEVICES – SERIES 400

SINGLE TEST DEVICES – SERIES 36

APPLICATIONS AND BEST PRACTICE

ISOLATION TESTING WITH ETL TEST EQUIPMENT

Isolation Testing: Essential for Electrical Safety and Efficiency

ETL-Prüftechnik GmbH: Your Expert for Isolation Testing

Isolation testing is a central aspect in the maintenance and safety of electrical systems. At ETL-Prüftechnik GmbH, we prioritize offering comprehensive solutions for effective isolation testing to our customers. Isolation testing, also known as insulation resistance testing, is essential to ensure the integrity and reliability of electrical installations.

What is Isolation Testing?

Isolation testing is the process of measuring the insulation resistance of electrical devices and systems. This test aims to ensure that the insulation in a facility is sufficient to guarantee safe operation. A high insulation resistance indicates good insulation, while low values may indicate potential hazards such as short circuits or electric shocks. Isolation testing is therefore an indispensable tool for monitoring and maintaining the safety and performance of electrical systems.

Conducting Isolation Testing:

Steps for Optimal Results:

Preparation: Before starting isolation testing, it is crucial to ensure that the system is de-energized. A thorough inspection of the test equipment, preferably one from ETL-Prüftechnik GmbH, is also essential.

Connecting the Test Equipment: For accurate isolation testing, the isolation test device is connected to the corresponding components of the system. A secure connection is essential for precise measurements of insulation resistance.

Setting and Measurement: The test voltage is set on the device according to the requirements of the installation. The measurement of insulation resistance is carried out by applying this voltage.

Evaluation: The results of the isolation test provide insights into the condition of the insulation. High insulation resistance values confirm integrity, while low values indicate deficiencies.

Isolation testing is not only a matter of safety but also of efficiency. A high insulation resistance ensures optimal performance and longevity of electrical installations. At ETL-Prüftechnik GmbH, we understand the importance of isolation testing and offer high-quality test equipment to enable our customers to make reliable and precise measurements of insulation resistance. With our expertise in isolation testing, we contribute to ensuring the safety and performance of electrical systems.

Request your inquiry now
quickly and effortlessly!

REQUEST NOW!

Click here to get to the testing device in two minutes – fast, easy, and without obligation.

Answer questions, provide contact details, and you’re done!
We will definitely get in touch with you.

Request your inquiry now
quickly and effortlessly!